IZ27B Wideband TEMPEST Digital Receiver 100Hz-18GHz

IZ27B Receiver is specifically designed for tempest measurement according to NATO SDIP-27/2 and EU IASG 07-03 with focus on test automation. The receiver is usually installed in a rack next to the shielded chamber. The receiver has no display and is operated from a computer connected over network. The receiver satisfies SDIP-27 Level A for connection to classified networks. Due to very good shielding of the receiver it is not required to install the receiver in a special shielded room.
Category:
Tempest
SubCategory:
Measurement System of Compromising Emanation

Description

IZ27B Receiver is specifically designed for tempest measurement according to NATO SDIP-27/2 and EU IASG 07-03 with focus on test automation. The receiver is usually installed in a rack next to the shielded chamber. The receiver has no display and is operated from a computer connected over network. The receiver satisfies SDIP-27 Level A for connection to classified networks. Due to very good shielding of the receiver it is not required to install the receiver in a special shielded room.

Features

  • High repeatability due to digital signal processing
  • Built-in RF generator
  • Built-in trigger generator
  • High sensitivity preamplifiers
  • High selectivity preselection filters
  • Gaussian and Flat filters
  • Automatic self-calibration and diagnostic
  • Powerful digital signal processing in the FPGA
  • High capacity acquisition memory
  • High speed PCI-E and LAN interfaces
  • AM and FM demodulations required for TEMPEST
  • USB and LSB demodulations for audio tests
  • EMI measurement according to MIL-STD 461G
  • Video and IF outputs
  • Resistance to vibrations
  • Tempest level EMC/EMI Shielding

Technical Specification

Parameter Value
Frequency Range 100Hz to 18GHz
Frequency resolution <0.1 Hz
RF Inputs INPUT A and INPUT B, 50Ω N Connectors
Preselector 22 low pass filters
14 high pass filters
50MHz wide YIG tracking filter 2 GHz–18 GHz
500MHz wide YIG tracking filter 6 GHz–18 GHz
Demodulation bandwidth 1Hz to 550MHz (1.8GHz without preselection)
Filter bandwidth steps At least 1-2-3-4-5-6-7-8-9
Noise figure <4dB up to 3GHz, <7dB up to 18GHz
Minimum detectable signal -170 dBm (1 Hz bandwidth, 1 GHz frequency)
Maximum input power range 30 dBm (1 W)
Input attenuator range 80dB in 1dB steps
ADC resolution 16bits (up to 225MS/s), 12bits (up to 3.6GS/s)
ADC sampling rate Programmable up to 3.6GS/s
Acquisition memory 4 GB
Phase and noise limited ADC range >150 dB/Hz
Amplitude measurement range >100 dB (100 kHz bandwidth)
Calibration generation - Frequency range: 100 Hz to 20 GHz
Calibration generation - Frequency resolution <0.1 Hz
Calibration generation - RF Level -100 dBm to 0 dBm
Calibration generation - RF level resolution 0.1 dB
Calibration generation - Phase noise (<-120dBc/Hz at 10kHz offset on 10 GHz)
Reference frequency 10MHz, <0.1 ppm frequency stability
Data Interfaces Ethernet 10/100/1000 Mbits/s
PCI-Express (4 lanes)
Fibre optic 10Gbits/s (optional)
IF output Analogue output of 1.25GS/s DAC, Bandwidth up to 400MHz (optional)
VIDEO output Analogue output of 1.25GS/s DAC,
Bandwidth up to 400MHz (optional)
Operating temperature 0 °C to +55 °C
Power Line supply AC 110 V–230 V/50 Hz–60 Hz
Power consumption < 180 W
Dimensions 0.474m × 0.429m × 0.179m (4U height 19”)
Weight < 35 kg